respiratoryCare

Purpose: The table contains information related to respiratory care. Patient data includes sequence of records for historical ordering, airway type/size/position, cuff pressure and various vent details including vent start and end dates/times, pressure limits, etc.

Links to:

  • PATIENT on patientUnitStayID

Table columns

Name Datatype Null Option Comment Is Key Stored Transformed Created
patientUnitStayID int NOT NULL foreign key link to the patient table FK C
respCareID int IDENTITY surrogate key for the respiratory data PK C
respCareStatusOffset int NOT NULL number of minutes from unit admit time that the respiratory value was entered C
currentHistorySeqNum int NULL the sequence number of the records for historical ordering S
airwayType varchar(30) NULL the airway picklist type input into the respiratory care status e.g.: Laryngectomy, Tracheostomy, Oral ETT, etc. S
airwaySize varchar(10) NULL the picklist airway size input into the respiratory care status e.g.: 35F, 9.5, NULL S
airwayPosition varchar(32) NULL picklist airway position for the patient e.g.: 23 @ lip, 26 @ teeth, 20, etc. S
cuffPressure decimal(5,1) NULL the picklist cuff pressure of the patient e.g.: 23.0, 22.0, NULL, etc. S
ventStartOffset int NULL number of minutes from unit admit time that the vent was started C
ventEndOffset int NULL number of minutes from unit admit time that the vent was ended C
priorVentStartYear smallint NULL year when the prior vent started T
priorVentStartTime24 time(0) NULL time in 24 hour format of when the prior vent start event occurred e.g.: “12:45”, “15:30”, “3:45” T
priorVentStartTime varchar(20) NULL time frame when the prior vent started: ‘midnight’, ‘morning’, ‘midday’, ‘noon’, ‘evening’, or ‘night’ T
priorVentStartOffset int NULL number of minutes from unit admit time that the prior vent was started C
priorVentEndYear smallint NULL year when the prior vent ended T
priorVentEndTime24 time(0) NULL time in 24 hour format of when the prior vent event ended e.g.: “12:45”, “15:30”, “3:45” T
priorVentEndTime varchar(20) NULL time frame when the prior vent ended: ‘midnight’, ‘morning’, ‘midday’, ‘noon’, ‘evening’, or ‘night’ T
priorVentEndOffset int NULL number of minutes from unit admit time that the prior vent was ended C
apneaParams varchar(80) NULL the picklist apnea parameters of the vent e.g.: set, on, done, etc. S
lowExhMVLimit decimal(11,4) NULL the low Ex MV Limit of the vent e.g: 5.0000, 200.0000, 3.0000, etc. S
hiExhMVLimit decimal(11,4) NULL the high Ex MV Limit of the vent e.g.: 18.000, 20.0000, 40.0000, etc. S
lowExhTVLimit decimal(11,4) NULL the low Exh TV limit of the vent e.g.: 300.0000, 200.0000, 350.0000, etc. S
hiPeakPresLimit decimal(11,4) NULL the high peak pressure limit of the vent e.g.: 45.0000, 65.0000, 50.0000, etc. S
lowPeakPresLimit decimal(11,4) NULL the low peak pressure limit of the vent e.g.: 10.0000, 150.0000, 15.0000, etc. S
hiRespRateLimit decimal(11,4) NULL the high respiration rate limit of the vent e.g.: 40.0000, 32.0000, 24.0000, etc. S
lowRespRateLimit decimal(11,4) NULL the low respiration rate limit of the vent e.g.: 12.0000, 5.0000, 8.0000, etc. S
sighPresLimit decimal(11,4) NULL the sigh pressure limit of the vent S
lowIronOxLimit decimal(11,4) NULL the low iron ox limit of the vent e.g.: 90.0000, 40.0000, 0.0000, etc. S
highIronOxLimit decimal(11,4) NULL the high iron ox limit of the vent e.g.: 100.0000, 120.0000, 90.0000, etc. S
meanAirwayPresLimit decimal(11,4) NULL the mean airway pressure limit of the vent e.g.: 60.0000, 45.0000, 50.0000, etc. S
PEEPLimit decimal(11,4) NULL the PEEP limit of the vent e.g.: 10.0000, 14.0000, 8.0000, etc. S
CPAPLimit decimal(11,4) NULL the CPAP limit of the vent e.g.: 2.0000, 10.0000, 5.0000, etc. S
setApneaInterval varchar(80) NULL the picklist apnea interval of the vent e.g.: .20, 1:5, 20 sec, etc. S
setApneaTV varchar(80) NULL the picklist apnea TV of the vent e.g.: 300, 460, 800, etc. S
setApneaIPPEEPHigh varchar(80) NULL the picklist apnea IPPEEP high of the vent e.g.: 5, 7.0, 3.0, etc. S
setApneaRR varchar(80) NULL the apnea RR of the vent e.g.: 20, 10, 28, etc. S
setApneaPeakFlow varchar(80) NULL th picklist e apnea peak flow of the vent e.g.: .80, 70, 100, etc. S
setApneaInspTime varchar(80) NULL the picklist apnea insp time of the vent e.g.: 096, 80, .7, etc. S
setApneaIE varchar(80) NULL the picklist apnea IE of the vent e.g.: 1:2, 1:5, 1:3, etc. S
setApneaFIO2 varchar(80) NULL the picklist apnea FIO2 of the vent e.g.: 1.0, 100, 100%, etc. S
eICU-CRD v2.0 documentation